Kelvara K-series • electric tankless water heater

Hot water thatdoesn't run out.

A wall-mounted heater the size of a carry-on that warms water only as it flows. Size it to the taps you run at once and the water in your pipes, then compare it with the tank it replaces.

11–27 kW
Four sizes
45 cm
Tall, on the wall
0 kWh
Standby loss
A square rain shower head pouring water against dark tiles
Morning shower • K24
11 °C in
40 °C out
11.5 L/min
23.3 kW
Installed by a licensed electrician and plumber. Check local codes and permits before you buy.
01 • Your peak

Size it for the taps you run at once.

A tankless heater has no store to lean on, so it must keep up with every hot tap open at the same moment. Pick a moment of your day or switch fixtures on in the house.

BathroomMain bathKitchenLaundry Kelvara
Each model at a 30 °C rise
11.5 L/min
K11
K18
K24
K27
A moment
Hot taps open
Peak hot-water flow
11.5 L/min
Running at once
2

Flows are typical for water-saving fixtures; your own fixtures may differ. Appliances such as dishwashers only draw hot water while they fill.

02 • Temperature rise

Cold pipes ask for more power.

The heater lifts water from ground temperature to the tap. Colder inlet water means a bigger rise, and a bigger rise needs more kilowatts for the same flow.

Where you live
Season
Hot water at the tap
40 °C
Peak flow from above
11.5 L/min
0102030405060 11°C 40°C Inlet water At the tap
Inlet water
11 °C
Rise
29 °C
Power needed
23.3 kW
Smallest that keeps up
K24
Covers your peak at this rise
Power by model
Your peak
K11
up to 5.4 L/min
K18
up to 8.9 L/min
K24
up to 11.9 L/min
K27
up to 13.3 L/min

Inlet temperatures are typical ground-water values for each kind of climate; your utility can tell you yours. Sizes assume a 240 V supply.

03 • Back-to-back showers

The fourth shower stays hot.

A tank mixes in cold as its store empties. Tankless warms water as it passes, so every shower is as hot as the first while the flow stays within the model's power.

Compare with a tank
Shower head
Showers in a row
4
Tank
Kelvara K24
8.5 L/min per shower
0°C20°C40°C60°C Target 40°C Tank runs cool Shower 1Shower 2Shower 3Shower 4Shower 5Shower 6 081624324048 min
Tank stays hot for
25 min
Hot showers, tank
3 of 4
Hot showers, Kelvara
4 of 4
Kelvara outlet
40.0 °C

Illustrative: tank stored at 60 °C with 70% usable before the outlet sags and a 3 kW element topping it up; 8-minute showers. Real tanks, mixing valves and pipe runs vary.

04 • Standby loss

Stop paying to keep a tank warm.

A tank loses heat through its walls all day, used or not. Tankless only spends energy while a tap is open. The tank size comes from the section above.

People at home
3
Hot water use
Electricity price
$0.22/kWh
Heating water
Standby loss
150 L tank
Tank
2,491 kWh • $548 a year
Kelvara
1,865 kWh • $410 a year
Lost to standby
548 kWh
22% of the tank's energy
Illustrative saving
$138
626 kWh a year

Illustrative estimate: water heated through the rise above, tank 95% and tankless 99% efficient, standby from typical tank ratings. Your use, tariff and installation change the result. Rebates and incentives vary by area and are never guaranteed.

05 • Space

Give the closet back.

Drawn to the same scale: the tank you compared above, and the Kelvara on the wall. Pick what the freed floor becomes.

View
The freed floor becomes
Floor space back
0.44 m²
Cupboard space freed
277 L
On the wall
45 x 37 x 11 cm
Tank footprint
Ø 56 x 120 cm
050100150200 cm 150 L tank K24 Free floor Tank closet from above Kelvara closet from above

Footprint includes 5 cm clearance around the tank. Keep the clearances your installer and local code require around the wall unit.

06 • Electrical check

Will your panel carry it?

Whole-home models draw a lot of current while a tap runs. Tell us what your panel already powers for a first, illustrative check before your electrician's load calculation.

Model
Main service
Already on the panel
200 A MAIN
Likely fits: confirm with your electrician
80% of main
In use
Heater
Heater draws
100 A
2 x 50 A double-pole
In use, estimated
56 A
Spare to 80%
104 A
Breaker spaces
16 of 20
Enough breaker spaces for the new circuits
Before install day
A licensed electrician confirms the load calculation
Dedicated circuits and breakers as rated
A licensed plumber fits shut-off and flushing valves
Permit and inspection per local code
Water pressure of at least 1 bar

Illustrative only, not a load calculation: we assume general circuits of 30 A plus 40% of the large appliances you pick. Only a licensed electrician can confirm your service and code requirements.

07 • Your install

Unit, install and extras.

The model comes from your rise above. Two add-ons with an install take $40 off; three or more take $75.

1
Heater
K11
11 kW
≈ 5.4 L/min at a 29 °C rise
$389
K18
18 kW
≈ 8.9 L/min at a 29 °C rise
$549
K24
24 kW
≈ 11.9 L/min at a 29 °C rise
$649
K27
27 kW
≈ 13.3 L/min at a 29 °C rise
$729
2
Installation
My own pros
$0
Install guide for your licensed electrician and plumber
Kelvara install
$520
Licensed electrician and plumber, permit filed where required
Install + panel check
$640
Adds a load calculation before install day
3
Extras
Scale guard cartridge
$49
Slows limescale in hard-water areas
Isolation valve kit
$59
Makes yearly flushing a 10-minute job
5-year cover
$89
Parts and labour, on top of the warranty
Point-of-use mini 3.5 kW
$179
For a far-away basin
A bright walk-in shower with marble-look tiles and black fittings
Your install
Kelvara K24
$649
Kelvara install
$520
Scale guard cartridge
$49
Isolation valve kit
$59
5-year cover
$89
Point-of-use mini 3.5 kW
$179
Bundle saving
−$40
Total
$1,277
or 12 payments of $106.42
where financing is offered, subject to approval
Reserve install date
Free delivery • 10-year heat-exchanger warranty
Homes on Kelvara

What households noticed first.

4.7
from 1,860 homes
By household size
1–2 people
4.8
3–4 people
4.7
5+ people
4.5
K27
Fourth shower, still hot

“Three teenagers and me. The last one in used to get the cold end of the tank. Now nobody checks the time.”

Dana R.
Columbus, OH
4 people • 2 showers
K24
Got a closet back

“The old 200-litre tank lived in the laundry. The K24 hangs where the shelf was and the floor is ours again.”

Tomás L.
Sacramento, CA
3 people • 1 shower
K27
The sizer was honest

“It told me our cold winter inlet needed the K27, not the K18 I was eyeing. Glad I listened.”

Ingrid S.
Duluth, MN
2 people • 1 shower
K24
Electrician signed it off

“We did the panel check first. The installer confirmed the load, added the breakers and filed the permit.”

Marcus O.
Raleigh, NC
5 people • 2 showers